Endress+HauserFLOWSIC

FLOWSIC600-XT

Ultrasonic FlowmeterFLOWSIC - IFL6XT

Custody transfer natural gas measurement with intelligent diagnostic functions

Overview

Product Description

FLOWSIC600-XT is available in variants with 4, 4+1, 4+4, and 8 measurement paths. In addition to the OIML R 137 Class 1.0 requirements, FLOWSIC600-XT meets the requirements of Class 0.5 and AGA9 in their entirety. FLOWSIC600-XT contains i-diagnostics™ – an intelligent application diagnostics function – and PowerIn Technology™ for continuous measurement operation for up to three weeks in the event of a mains voltage failure. For the very best possible measurement accuracy and long-term stability.

Key Benefits

  • Low measurement uncertainty in every application
  • Excellent measurement data reliability and availability
  • The right ultrasonic gas flow measuring device for every application – without compromise
  • Simple device integration – even in compact systems
  • Quick and easy commissioning and checks
  • Economical quantification of the H2 content in natural gas

Specifications

Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Measured variables
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Nominal pipe size
3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request

Measuring task

Measured variables
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Repeatability
≤ 0.05 % of the measured value (typical)
Accuracy
4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated   4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench.   4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
Medium temperature range
–46 °C ... +180 °C / -51 °F ... +356 °F On request:–194 °C ... +280 °C / –381 °F ... +536 °F
Operating pressure range
0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
Nominal pipe size
3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request
Metrological approvals and certificates
OIML R 137-1&2:2012 (class 0.5) OIML D 11:2013 ISO 17089-1 AGA-Report Nr. 9 MID: 2014/32/EU PED: 2014/68/EU ASME: B16.5, B16.47 A/B ATEX: 2014/34/EU EMC: 2014/30/EU GOST 8.611-2013 GOST 8.733-2011 CPA: JJG1030-2007 PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017
Hazardous area approvals
IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb  Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb Ex ia op is IIA/IIC T4 Ga   ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb II 1G Ex ia op is IIA/IIC T4 Ga NEC/CEC (US/CA) Explosion-proof / non-incendive: CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb Intrinsically safe: CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
Digital Outputs
4 outputs: 2 x status, 2 x pulse: ≤ 30 V, 50 mA Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable)
Digital communication
Modbus TCP

Industries:Oil & gasPower & energy