Proline Prowirl D 200
Wafer flowmeter, available as compact or remote version. For all basic applications and for 1-to-1 replacement of orifice plates.
Overview
Product Description
Prowirl D 200 can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. The genuine loop-powered technology allows for seamless integration into existing infrastructures. Prowirl D offers highest operational safety in hazardous areas and Heartbeat Technology enables process safety at all times.
Key Benefits
- Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
- Integrated temperature measurement for mass/energy flow of saturated steam
- Easy alignment of the sensor thanks to included centering rings
- High availability – proven robustness, resistance to vibrations, temperature shocks and water hammer
- Long-term stability – robust drift-free capacitive sensor
Specifications
- Max. process pressure
- PN 40, Class 300, 20K
- Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
- Max. measurement error
- Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
- Measuring range
- Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
- Wetted materials
- Measuring tube: 1.4408 (CF3M) DSC sensor: 1.4435 (316/316L)
Measuring task
- Product headline
- Cost-effective wafer flowmeter, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. For all basic applications and for 1-to-1 replacement of orifice plates.
- Sensor features
- Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
- Transmitter features
- Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
- Nominal diameter range
- DN 15 to 150 (½ to 6")
- Wetted materials
- Measuring tube: 1.4408 (CF3M) DSC sensor: 1.4435 (316/316L)
- Measured variables
- Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
- Max. measurement error
- Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass flow (liquid): ±0.85% Mass flow (steam, gas): ±1.7 %
- Measuring range
- Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
- Max. process pressure
- PN 40, Class 300, 20K
- Medium temperature range
- Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
- Ambient temperature range
- Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F)
- Sensor housing material
- Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
- Transmitter housing material
- AlSi10Mg, coated; 1.4404 (316L)
- Degree of protection
- Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure
- Display/Operation
- 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
- Outputs
- 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive)
- Inputs
- Current input 4‐20 mA (passive)
- Digital communication
- HART, PROFIBUS PA, FOUNDATION Fieldbus
- Power supply
- DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
- Hazardous area approvals
- ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
- Product safety
- CE, C-TICK, EAC
- Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
- Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
- Marine approvals and certificates
- ABS, LR, BV, DNV
- Pressure approvals and certificates
- PED, CRN
- Material certificates
- 3.1 material NACE MR0175/MR0103, PMI (on request)