Endress+Hausert-mass

Proline t-mass F 500

t-mass - 6F5B

Inline flowmeter with long-term stability as remote version with up to 4 I/Os. Measurement of utility and process gases as well as gas mixtures in small line sizes.

Overview

Product Description

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.

Key Benefits

  • Measuring principle is characterized by a high operable flow range and direct mass flow measurement
  • Measurement of utility and process gases as well as gas mixtures in small line sizes
  • Inline version with DN 15 to 100 (1/2 to 4")
  • Bidirectional measurement; high measuring performance
  • Patented drift-free sensor with SIL 2
  • Remote version with up to 4 I/Os
  • Backlit display with touch control and WLAN access
  • Standard cable between sensor and transmitter

Specifications

Max. process pressure
PN40 / Cl. 300 / 20K
Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Wetted materials
Measuring tubes • DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408 • DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L) Process connections Flange connections Stainless steel, 1.4404 (F316/F316L) Threaded connections Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional • Stainless steel, 1.4404 (316/316L) • Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L)
Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)

Measuring task

Product headline
Inline flowmeter with long-term stability as remote version with up to 4 I/Os. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in small line sizes.
Sensor features
High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor. Inline version with DN 15 to 100 (½ to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
Nominal diameter range
DN 15 to DN 100 (1/2" to 4")
Wetted materials
Measuring tubes • DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408 • DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L) Process connections Flange connections Stainless steel, 1.4404 (F316/F316L) Threaded connections Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional • Stainless steel, 1.4404 (316/316L) • Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L)
Measured variables
Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. process pressure
PN40 / Cl. 300 / 20K
Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)
Ambient temperature range
-40 to 60°C (-40 to 140°F) Optional: Transmitter: -50 to 60°C (-50 to 140°F), Sensor: -60 to 60°C (-60 to 140°F)
Transmitter housing material
Aluminium, AlSi10Mg, coated Polycarbonate
Degree of protection
IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)
Display/Operation
4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output
Inputs
Status input 4-20 mA input
Digital communication
HART, Modbus RS485
Power supply
DC 24V AC 100 to 240V
Hazardous area approvals
ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product safety
CE, C-tick
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material NACE MR0175/MR0103

Related products

t-mass - 65F

Industries:Power & energy