Proline t-mass F 500
Inline flowmeter with long-term stability as remote version with up to 4 I/Os. Measurement of utility and process gases as well as gas mixtures in small line sizes.
Overview
Product Description
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
Key Benefits
- Measuring principle is characterized by a high operable flow range and direct mass flow measurement
- Measurement of utility and process gases as well as gas mixtures in small line sizes
- Inline version with DN 15 to 100 (1/2 to 4")
- Bidirectional measurement; high measuring performance
- Patented drift-free sensor with SIL 2
- Remote version with up to 4 I/Os
- Backlit display with touch control and WLAN access
- Standard cable between sensor and transmitter
Specifications
- Max. process pressure
- PN40 / Cl. 300 / 20K
- Measuring range
- 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
- Max. measurement error
- Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
- Wetted materials
- Measuring tubes • DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408 • DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L) Process connections Flange connections Stainless steel, 1.4404 (F316/F316L) Threaded connections Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional • Stainless steel, 1.4404 (316/316L) • Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L)
- Medium temperature range
- -40 °C to +180°C (-40 °F to +356 °F)
Measuring task
- Product headline
- Inline flowmeter with long-term stability as remote version with up to 4 I/Os. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in small line sizes.
- Sensor features
- High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Easy maintenance – removable sensor. Inline version with DN 15 to 100 (½ to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.
- Transmitter features
- Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.
- Nominal diameter range
- DN 15 to DN 100 (1/2" to 4")
- Wetted materials
- Measuring tubes • DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408 • DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L) Process connections Flange connections Stainless steel, 1.4404 (F316/F316L) Threaded connections Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional • Stainless steel, 1.4404 (316/316L) • Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L)
- Measured variables
- Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
- Max. measurement error
- Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
- Measuring range
- 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
- Max. process pressure
- PN40 / Cl. 300 / 20K
- Medium temperature range
- -40 °C to +180°C (-40 °F to +356 °F)
- Ambient temperature range
- -40 to 60°C (-40 to 140°F) Optional: Transmitter: -50 to 60°C (-50 to 140°F), Sensor: -60 to 60°C (-60 to 140°F)
- Transmitter housing material
- Aluminium, AlSi10Mg, coated Polycarbonate
- Degree of protection
- IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)
- Display/Operation
- 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
- Outputs
- 4 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output
- Inputs
- Status input 4-20 mA input
- Digital communication
- HART, Modbus RS485
- Power supply
- DC 24V AC 100 to 240V
- Hazardous area approvals
- ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
- Product safety
- CE, C-tick
- Functional safety
- Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
- Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
- Pressure approvals and certificates
- PED, CRN
- Material certificates
- 3.1 material NACE MR0175/MR0103