Endress+HauserPromag

Promag 55S

Electromagnetic flowmeterPromag - 55S

The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics. Ideal for the most demanding applications with high solids content and high abrasion.

Overview

Specifications

Max. process pressure
PN 40, Cl. 300, JIS 20 K
Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. measurement error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s) Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Medium temperature range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum

Measuring task

Product headline
The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics. Superb signal stability due to unique signal processing. Ideal for the most demanding applications with high solids content and high abrasion.
Sensor features
Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Intensified coil system. Large range of liners. Solids content up to 80 % by weight.
Transmitter features
Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing. 4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.
Nominal diameter range
DN 15...600 1/2"...24"
Wetted materials
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Measured variables
Volume flow, electrical conductivity, mass flow
Max. measurement error
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s) Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. process pressure
PN 40, Cl. 300, JIS 20 K
Medium temperature range
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
Aluminum coated AlSi10Mg, carbon steel with protective varnish
Transmitter housing material
Powder-coated die-cast aluminum
Degree of protection
Standard: IP 67 (Type 4X enclosure) for transmitter and sensor Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor
Display/Operation
Liquid-crystal display: illuminated, four lines with 16 characters per line Onsite operation with three optical sensor keys
Outputs
4...20mA (active/passive) Pulse-/ Frequency output (active/passive) Two status outputs
Inputs
Status Current input
Digital communication
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Power supply
AC 20 to 260 V DC 20 to 64 V
Hazardous area approvals
ATEX, FM, CSA, UK Ex
Product safety
CE, C-tick, EAC marking
Pressure approvals and certificates
CRN, PED
Material certificates
3.1 material
Hygienic approvals and certificates
Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920

Related products

Speedmag - SPromag - 35S

Industries:Mining, Minerals & MetalsFood & beverageWater & wastewater