Promag D 10
Wafer flowmeter with easy-to-use operation concept, for basic water applications; optimized for limited space and plastic pipe installations.
Overview
Product Description
Proline Promag D 10 is a wafer flowmeter designed for water applications where space is constrained. Versions with touch screen or the Endress+Hauser SmartBlue app that can easily be operated. Optional Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
Key Benefits
- Easy mounting – space-saving wafer or threaded process connection
- Simple commissioning – wizard-guided parameterization in advance or in the field saves time
- Easy operation – optional LC display or Bluetooth connection guarantee intuitive handling
- Maintenance-free – no moving parts
Specifications
- Medium temperature range
- Liner material polyamide: 0 to +60°C (+32 to +140°F)
- Measuring range
- 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
- Max. process pressure
- PN 16, Class 150, 10K
- Max. measurement error
- Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Wetted materials
- Liner material polyamide: 0 to +60°C (+32 to +140°F) Electrodes: 1.4435 (316L)
Measuring task
- Product headline
- Highly cost-effective wafer flowmeter with easy-to-use operation concept. For basic water applications, optimized for limited space and plastic pipe installations.
- Sensor features
- Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Short face-to-face length and low weight. Integrated ground disks made of stainless steel. International drinking water approvals.
- Transmitter features
- Optimum usability – display with touch screen (HART and Modbus RS485 communication only) or operation with mobile devices and SmartBlue app. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology. 2-line display with push buttons. Device as compact or remote version. HART.
- Nominal diameter range
- DN 25 to 100 (1 to 4")
- Wetted materials
- Liner material polyamide: 0 to +60°C (+32 to +140°F) Electrodes: 1.4435 (316L)
- Measured variables
- Volume flow, mass flow
- Max. measurement error
- Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
- Measuring range
- 9 dm³/min to 282 m³/h (2.5 gal/min to 1250 gal/min)
- Max. process pressure
- PN 16, Class 150, 10K
- Medium temperature range
- Liner material polyamide: 0 to +60°C (+32 to +140°F)
- Ambient temperature range
- -40 to 60°C (-40 to 140°F)
- Sensor housing material
- DN 25 to 100 (1 to 12"): AlSi10Mg, coated
- Transmitter housing material
- Polycarbonat; AlSi10Mg, coated
- Degree of protection
- Compact version: IP66/67, type 4X enclosure Sensor remote version (standard): IP66/67, type 4X enclosure
- Display/Operation
- LCD display with touch & auto rotate
- Outputs
- 4-20 mA HART (active/passive), Pulse/frequency/switch output Modbus RS485, 4-20 mA
- Digital communication
- HART, MODBUS RS485
- Power supply
- DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
- Hazardous area approvals
- CSA, GP
- Product safety
- Product safety
- Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
- Hygienic approvals and certificates
- Hygienic approvals and certificates
Technical documents
Operational documents
Videos
Promo Video 1
Related products
Questions & answers
In addition to the touch screen (if selected), interfaces are available via SmartBlue app (if selected) and FieldCare/DeviceCare via FXA 195 or FXA 291.
The maximum frequency of the output is 10'000 kHz
The range is 10 m (32 ft) under standard conditions.
By default, the pulse output is set to "off". However, the setting can also be configured in advance when ordering via option 530;BD