Promag P 100
The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Overview
Specifications
- Wetted materials
- Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803)
- Max. process pressure
- PN 40, Class 300, 20K
- Max. measurement error
- Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
- Measuring range
- 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
- Medium temperature range
- Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Measuring task
- Product headline
- The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
- Sensor features
- Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.
- Transmitter features
- Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Local display available.
- Nominal diameter range
- DN 15 to 600 (½ to 24")
- Wetted materials
- Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803)
- Measured variables
- Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
- Max. measurement error
- Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
- Measuring range
- 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
- Max. process pressure
- PN 40, Class 300, 20K
- Medium temperature range
- Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
- Ambient temperature range
- Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
- Sensor housing material
- DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
- Transmitter housing material
- AlSi10Mg, coated
- Degree of protection
- IP66/67, type 4X enclosure
- Display/Operation
- 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible
- Outputs
- 4‐20 mA HART (active) Pulse/frequency/switch output (passive)
- Inputs
- None
- Digital communication
- HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
- Power supply
- DC 20 to 30 V
- Hazardous area approvals
- ATEX, IECEx, cCSAus, INMETRO
- Product safety
- CE, C-Tick
- Metrological approvals and certificates
- Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
- Marine approvals and certificates
- LR approval, DNV approval, ABS approval, BV approval
- Pressure approvals and certificates
- PED, CRN
- Material certificates
- 3.1 material
- Hygienic approvals and certificates
- Drinking water approval: ACS, NSF 61, WRAS