Endress+HauserPromag

Promag P 100

Electromagnetic flowmeterPromag - 5P1B

The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

Overview

Specifications

Wetted materials
Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803)
Max. process pressure
PN 40, Class 300, 20K
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

Measuring task

Product headline
The flowmeter for highest medium temperatures with an ultra-compact transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Sensor features
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.
Transmitter features
Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Local display available.
Nominal diameter range
DN 15 to 600 (½ to 24")
Wetted materials
Liner: PFA, PTFE Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium Duplex 1.4462 (UNS S31803)
Measured variables
Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Max. process pressure
PN 40, Class 300, 20K
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Ambient temperature range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
DN 15 to 300 (½ to 12"): AlSi10Mg, coated DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Transmitter housing material
AlSi10Mg, coated
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible
Outputs
4‐20 mA HART (active) Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO
Product safety
CE, C-Tick
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
Drinking water approval: ACS, NSF 61, WRAS

Related products

Promag - 53Promag - 50E

Industries:Water & wastewater